Atlas / PMMA film · opposed flow
BASS-II test B10
1-cm, 0.2-mm PMMA film, opposed flow, microgravity (ISS, Microgravity Science Glovebox). Principal investigator: Bhattacharjee. Listed date 2014-07-07
Quenched as flow was reduced
Conditions and sample
- Oxygen
- 20.1 % by volumeRecorded for this testTaken from NASA's 'Calibrated initial O2 vol%' column.
- Airflow as recorded
- 5, 4, 3, 2, 1 (changed during the test)Recorded for this test
- Starting airflow
- 5 cm/sDerived by MicroFire AtlasFirst value of the 'Air display' column (air velocity transducer, cm/s). Later 'pot' values are fan potentiometer settings, not velocities, and are not converted.
- Pressure
- 99.2–99.5 kPaStated for the whole test series: “The total pressure is also monitored, which varied from 99.2 to 99.5 kPa in the tests reported.” BASS-II Summary Report, §2.3.5, PDF p. 46Series-level range from the Bhattacharjee report section; not a per-test reading.
- Thickness
- 0.2 mmRecorded for this test
- Width
- 10 mmRecorded for this test
- Exposed length
- Not statedNot stated in the source
- Outcome code
- Quenched as flow was reducedDerived by MicroFire AtlasCoded by MicroFire Atlas from the verbatim observations column.
What the crew and ground team wrote
“Multiple velocities for steady spread, extinguished at pot 0.35”
Gas readings before and after the burn
| Initial | Final | |
|---|---|---|
| O₂, vol % | 20.1 | 19.9 |
| CO₂, vol % | 0.33 | 0.44 |
| CO, ppm | 0 | 23 |
Readings of the glovebox work volume, from NASA's table columns. They describe the enclosure, not the flame.