Skip to content

Atlas / SIBAL fabric · concurrent flow

BASS-II test GMT178-T17

composite cotton-fiberglass fabric blend (75 percent cotton and 25 percent fiberglass), concurrent flow, microgravity (ISS, Microgravity Science Glovebox)

Kept burning at high flow (no blowoff)

Conditions and sample

Oxygen
16.9 % by volumeRecorded for this test
Airflow as recorded
6 to 53 (changed during the test)Recorded for this test
Starting airflow
6 cm/sRecorded for this test
Final airflow
53 cm/sRecorded for this test
Pressure
101.325 kPa (1 atm)Stated for the whole test series: “Ambient pressure was 1 atm.” BASS-II Summary Report, §7.1.3, PDF p. 102
Thickness
0.32 mmStated for the whole test series: “The thickness of the sample is about 0.32 mm” BASS-II Summary Report, §7.1.3, PDF p. 102
Width
22 mmRecorded for this test
Exposed length
100 mmStated for the whole test series: “Both have an exposed length of 10 cm.” BASS-II Summary Report, §7.1.3, PDF p. 102
Outcome code
Kept burning at high flow (no blowoff)Derived by MicroFire AtlasCoded by MicroFire Atlas from the verbatim Comments column of Table 7.1.

What the crew and ground team wrote

“No blowoff”

Published findings about this test family

“The quenching speeds were found to be between 1 and 5 cm/s with higher speed in lower oxygen atmosphere.”
Reported observationSIBAL fabric in concurrent flow, abstract
“Flames spread more slowly across the narrower samples, at lower flow velocities and at lower O2 percentages.”
Reported observationBASS-II Summary Report, PDF p. 103