Skip to content

Atlas / PMMA film · opposed flow

BASS-II test B13

2-cm, 0.4-mm thick film, opposed flow, microgravity (ISS, Microgravity Science Glovebox). Principal investigator: Bhattacharjee. Listed date 2014-07-07

Quenched as flow was reduced

Conditions and sample

Oxygen
20.1 % by volumeRecorded for this testTaken from NASA's 'Calibrated initial O2 vol%' column.
Airflow as recorded
10, 5, 4, 3, 2, 1 (changed during the test)Recorded for this test
Starting airflow
10 cm/sDerived by MicroFire AtlasFirst value of the 'Air display' column (air velocity transducer, cm/s). Later 'pot' values are fan potentiometer settings, not velocities, and are not converted.
Pressure
99.2–99.5 kPaStated for the whole test series: “The total pressure is also monitored, which varied from 99.2 to 99.5 kPa in the tests reported.” BASS-II Summary Report, §2.3.5, PDF p. 46Series-level range from the Bhattacharjee report section; not a per-test reading.
Thickness
0.4 mmRecorded for this test
Width
20 mmRecorded for this test
Exposed length
Not statedNot stated in the source
Outcome code
Quenched as flow was reducedDerived by MicroFire AtlasCoded by MicroFire Atlas from the verbatim observations column.

What the crew and ground team wrote

“Multiple velocities for steady spread, extinguished at pot 0.35”

Gas readings before and after the burn

InitialFinal
O₂, vol %20.119.6
CO₂, vol %0.330.65
CO, ppm061

Readings of the glovebox work volume, from NASA's table columns. They describe the enclosure, not the flame.