Atlas / PMMA film · opposed flow

BASS-II test B17

1-cm-wide, 200-µm-thick PMMA, opposed flow, microgravity (ISS, Microgravity Science Glovebox). Principal investigator: Bhattacharjee. Listed date 2014-07-02

Quenched as flow was reduced

Conditions and sample

Oxygen
16.6 % by volumeRecorded for this testTaken from NASA's 'Calibrated initial O2 vol%' column.
Airflow as recorded
5, 3, pot 0.4 (changed during the test)Recorded for this test
Starting airflow
5 cm/sDerived by MicroFire AtlasFirst value of the 'Air display' column (air velocity transducer, cm/s). Later 'pot' values are fan potentiometer settings, not velocities, and are not converted.
Pressure
99.2–99.5 kPaStated for the whole test series: “The total pressure is also monitored, which varied from 99.2 to 99.5 kPa in the tests reported.” BASS-II Summary Report, §2.3.5, PDF p. 46Series-level range from the Bhattacharjee report section; not a per-test reading.
Thickness
0.2 mmRecorded for this test
Width
10 mmRecorded for this test
Exposed length
Not statedNot stated in the source
Outcome code
Quenched as flow was reducedDerived by MicroFire AtlasCoded by MicroFire Atlas from the verbatim observations column.

What the crew and ground team wrote

“Burned steadily at higher flows, extinguished just as we reached a pot of 0.4; vapor jetting more on bottom, possibly because of sample tilted slightly to flow?”

Gas readings before and after the burn

InitialFinal
O₂, vol %16.616.5
CO₂, vol %0.20.34
CO, ppm047